Hydrothermal Autoclave

We are a leading Manufacturer of hydrothermal autoclave reactor, hydrothermal autoclave 100ml, hydrothermal autoclave 200ml, hydrothermal autoclave 150ml, teflon lined hydrothermal autoclave and hydrothermal autoclave 500 ml from Faridabad, India.

Hydrothermal Autoclave Reactor

Request Callback

Get Latest Price

Product Brochure
Capacity500 ml
MaterialSS316
BrandHarrier
Warranty5 Years SS Parts & 1 Year PTFE
Temperature Range260
Working Pressure3MPa or 30 Bar
Automation GradeAutomatic
Country of OriginMade in India
Usage/ApplicationLaboratory
Voltage380 V
PhaseSingle
Frequency50 Hz
Temperature240-260 Degree C
Inner ShellPTFE
Safety FeaturesDouble Locking

Minimum order quantity: 1 100 Pieces

Details:
  • Hydrothermal autoclave, It is used for the hydrothermal synthesis reacon. It is inner PTFE lined and outer made from stainless steel. It is operated at high pressure and high temperature.

Available Size
  • 25 ml
  • 50 ml
  • 100 ml
  • 250 ml
  • 500 ml
  • 1000 ml

Hydrothermal Autoclave 100ml

Request Callback

Get Latest Price

Product Brochure
Capacity10ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30 Bar
Size10ML
Working Pressure3MPa or 30 Bar
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 100 Pieces

A hydrothermal autoclave with a capacity of 10 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 100ml

Request Callback

Get Latest Price

Product Brochure
Capacity100ML
Temperature Range260 DegreeC
Pressure Range+-3 MPA or 30 Bar
Size100ML
Working Pressure3 mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 100 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 200ml

Request Callback

Get Latest Price

Product Brochure
Capacity200 ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size200ML
Working Pressure3mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 200 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave Reactor

Request Callback

Get Latest Price

Product Brochure
Capacity1000ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size1000ML
Working Pressure3 mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 1000 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 150ML

Request Callback

Get Latest Price

Product Brochure
Capacity150ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size150ML
Working Pressure260
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Unit

A hydrothermal autoclave with a capacity of 150 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Teflon Lined Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity100 ml
Materialss 304,316
Warranty1 year
Temperature Range260 degree
Working Pressure3MPa or 30 Bar
Country of OriginMade in India

Minimum order quantity: 1 100 Pieces

The Hydrothermal Autoclave Reactore use to carry hydrothermal reaction at high pressure and high temperature sythisis reactore generally comes in a two veriety;
the frist is PTFE lined hydrothermal autoclave reactores. hydrothermal reactore mainly made up of two partrs; outer high-quality stainless-steel (304 & 316 customer on Demand) jacket and inner PTFE liner chamber. 
in the Teflon-lined autoclave, the reaction is carried out at maximum 260 degree
(500) Fahrenheit).
this product extensively used in the scientific laboratory, research and development labs,
institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 500 ML

Request Callback

Get Latest Price

Product Brochure
Capacity500 ML
Warranty12 Months
Temperature Range260 Degree Celsius
Pressure Range+-3MPA or 30Bar
Size500 ML
Working Pressure3MPa or 30 Bar
Country of OriginMade in India
Heating and Cooling Rate+-5 Degree Celsius/min

Minimum order quantity: 01 100 Pieces

A hydrothermal autoclave with a capacity of 500 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 200ml

Request Callback

Get Latest Price

Product Brochure
Capacity2000 ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size2000 ML
Working Pressure3MPa or 30 Bar
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Unit

A hydrothermal autoclave with a capacity of 2000 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 250ml

Request Callback

Get Latest Price

Product Brochure
Capacity250 ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size250 ML
Working Pressure3 Mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 250 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave 25 ML

Request Callback

Get Latest Price

Product Brochure
Capacity25ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size25ML
Working Pressure3mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 25 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave Reactor

Request Callback

Get Latest Price

Product Brochure
Capacity25 ml
MaterialStainless Steel
BrandHarrier
Warranty1 Year's
Working Pressure3MPa or 30 Bar
Country of OriginMade in India
Usage/ApplicationLab & Pharma
ShapeHorizontal
Automation GradeManual
Insulation WallSingle Wall

Minimum order quantity: 1 100 Pieces

Details:
  • Hydrothermal autoclave, it is used for the hydrothermal synthesis reaction. It is inner Teflon lined and outer made from stainless steel (304). It is operated at high pressure and high temperature. 

Stainless Steel Hydrothermal Autoclave Threaded Model

Request Callback

Get Latest Price

Product Brochure
Capacity150 ml
Warranty1
Pressure Range3 MPA
Temperature Range260
Country of OriginMade in India

Minimum order quantity: 1 Piece

  • Hydrothermal Autoclave: 100 ml
  • Maximum operating temperature: ≤260°C
  • Working temperature: – 260°C
  • Working Pressure: ≤3MPa or 30 Bar
  • Heating and Cooling Rate: ≤5°C/min
  • Material: Shell made of high-quality nonmagnetic 304 stainless steel
  • Easy to handle
  • Threads are very smooth to lock and unlock
  • Can be customized as per requirement
  • Primary screw type cap for basic tightening
  • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage
  • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

High Pressure Hydrothermal Autoclaves

Request Callback

Get Latest Price

Product Brochure
Capacity100 ml
MaterialStainless Steel
Warranty12 Months
Temperature Range260
Pressure Range3 MPA
Packaging TypeCarton Box
Country of OriginMade in India

Minimum order quantity: 1 Piece

High Pressure Hydrothermal Autoclave: -
Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED)     

Description:


The High Pressure Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Specifications of PTFE Lined Autoclave:



  • Hydrothermal Autoclave: 5 to 5000 ml
  • Maximum operating temperature: ≤260°C
  • Working temperature: – 260°C
  • Working Pressure: ≤3MPa or 30 Bar
  • Heating and Cooling Rate: ≤5°C/min
  • Material: Shell made of high-quality nonmagnetic 304 stainless steel
  • Easy to handle
  • Threads are very smooth to lock and unlock
  • Can be customized as per requirement
  • Primary screw type cap for basic tightening
  • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage
  • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity100 ml
BrandHarrier
MaterialStainless Steel
Temperature Range260
Working Pressure3 Mpa
Country of OriginMade in India
ShapeCircular
Automation GradeManual
Usage/ApplicationLaboratory
Insulation WallTriple Wall

Minimum order quantity: 1 Piece

  • Hydrothermal autoclave, it is used for the hydrothermal synthesis reaction. It is inner Teflon lined and outer made from stainless steel (304). It is operated at high pressure and high temperature. 

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity50ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30 Bar
Size50ML
Working Pressure3 mpa
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Piece

A hydrothermal autoclave with a capacity of 50 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity400 ML
Warranty12 Months
Temperature Range260 Degree Celsius
Pressure Range+-3MPA or 30Bar
Size400 ML
Working Pressure250
Country of OriginMade in India
Heating and Cooling Rate+-5 Degree Celsius/min

Minimum order quantity: 01 Unit

A hydrothermal autoclave with a capacity of 400 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity5000 ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size5000 ML
Working Pressure3MPa or 30 Bar
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Unit

A hydrothermal autoclave with a capacity of 5000 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity300 ML
Warranty12 Months
Temperature Range260 DegreeC
Pressure Range+-3MPA or 30Bar
Size300 ML
Country of OriginMade in India
Heating and Cooling Rate+-5 DegreeC/min

Minimum order quantity: 01 Unit

A hydrothermal autoclave with a capacity of 300 ml is a specialized laboratory tool used for conducting chemical reactions under high-temperature and high-pressure conditions. Hydrothermal synthesis reactors generally come in two varieties; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor is mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product is extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity100 ml
MaterialStainless Steel
Warranty1
Pressure Range3 MPA
Temperature Range260
Country of OriginMade in India

Minimum order quantity: 1 Piece

  • Hydrothermal Autoclave: 100 ml
  • Maximum operating temperature: ≤260°C
  • Working temperature: – 260°C
  • Working Pressure: ≤3MPa or 30 Bar
  • Heating and Cooling Rate: ≤5°C/min
  • Material: Shell made of high-quality nonmagnetic 304 stainless steel
  • Easy to handle
  • Threads are very smooth to lock and unlock
  • Can be customized as per requirement
  • Primary screw type cap for basic tightening
  • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage
  • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity100 ml
MaterialStainless Steel
Warranty12 Months
Temperature Range260
Pressure Range3 Mpa
Packaging TypeCarton Box
Country of OriginMade in India

Minimum order quantity: 1 Piece

Hydrothermal Autoclave: -
Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED)     

Description:


The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc.

Specifications of PTFE Lined Autoclave:



  • Hydrothermal Autoclave: 50 & 100 ml
  • Maximum operating temperature: ≤260°C
  • Working temperature: – 260°C
  • Working Pressure: ≤3MPa or 30 Bar
  • Heating and Cooling Rate: ≤5°C/min
  • Material: Shell made of high-quality nonmagnetic 304 stainless steel
  • Easy to handle
  • Threads are very smooth to lock and unlock
  • Can be customized as per requirement
  • Primary screw type cap for basic tightening
  • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage
  • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Industrial Hydrothermal Autoclave

Request Callback

Get Latest Price

Product Brochure
Capacity500 ML TO 10 Liters
BrandHarrier
Warranty12 Month
Pressure RangeWorking Pressure: 3MPa or 30 Bar
MaterialSS 304 & 316
Temperature Range260 to 800 DegreeC
Working Pressure3 Mpa
Country of OriginMade in India

Minimum order quantity: 01 Piece

Hydrothermal Autoclave: -

Make: HE (GMP / ISO 9001 – 2015 / CE Mark)

 

Description:

 

The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure

and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the

first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors.

Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304

& 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined

autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit),

while the safe temperature is 240-degree Celsius (464 Fahrenheit). This product

extensively used in the scientific laboratory, research and development labs, institutional

organizations, quality analysis section in industries etc.

Specifications of PTFE Lined Autoclave:

 

Hydrothermal Autoclave: 500 ml to 2 Liters.

Maximum operating temperature: ≤260°C

Safe temperature: – 250°C

Working Pressure: ≤3MPa or 30 Bar

Heating and Cooling Rate: ≤5°C/min

Material: Shell made of high-quality nonmagnetic 304 stainless steel

Easy to handle

Threads are very smooth to lock and unlock

Can be customized as per requirement

Primary screw type cap for basic tightening

Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt)

for extra tightening to avoid leakage

Customized stainless-steel jacket/autoclave of SS 316 can also be provided if

needed, which is better for corrosive materials.

 

X

Contact Us

Prince (Manager)
Harrier Enterprises
First Floor ,Block-1, H.No-210, SDV Lakkarpur,Poll Factory
Surajkund Faridabad, Faridabad - 121009, Haryana, India

Get Directions
Send Email
Share: